Sun Microsystems CP3240 Switch User Manual


 
3-2 Sun Netra CP3240 Switch Installation Guide September 2009
3.1 Jumper Settings
The following jumper settings are available for configuring the switch. Each of
jumper settings is described in the subsections.
3.1.1 P4 Cross-Connect Control
This jumper is used to control ShMC cross connect. ShMC cross connect is the
ability to connect to two ShMCs at 10/100 each rather than use a single 10/100/1000
for a single ShMC. The first ShMC port is number 1 on the Base. The second ShMC
port is number 17 on the Base.
TABLE 3-1 Switch Configuration Jumper Settings
Jumper Default Purpose
P4 L2 Cross Connect Control
P6(1-2) OFF Fabric Zero Reset Configuration Word
P6(3-4) OFF Base Zero Reset Configuration Word
P8(1-2) OFF Base Write Protect Disable
P8(3-4) OFF Fabric Write Protect Disable
P9 OFF IPMC Firmware Write
P10(1-2) OFF IPMC Disable
P10(3-4) OFF IPMC FWE
P11(1-2) OFF Forced Board Enable
P11(3-4) OFF IPMC Board Reset Disable
P12 OFF EMI Ground to Logic Ground
P13 OFF Serial Direction
TABLE 3-2 P4 Cross-Connect Jumper Settings
P4 Default Function
OFF Software control of cross connect.
1-2 Default Force cross connect enabled, base channel 1 is two 10/100BaseTX
ports.
3-4 No cross connect; base channel 1 is 10/100/1000Base-T.