Sun Microsystems CP3240 Switch User Manual


 
Chapter 1 Getting Started 1-7
1.6.1 Base 10/100/1000 Uplink Ports (RJ-45)
There are two front panel Base 10/100/1000Base-T Ethernet uplink ports on the
faceplate. They are ports number 18 and 19 on the Base network.
1.6.2 10/100 Management Port (RJ-45)
There is a 10/100 management Ethernet port on the faceplate. This port can be used
to manage the Base and Fabric. This port and the 10/100 management port on the
RTM can be used at the same time.
1.6.3 Serial Management Port (RJ-45)
There is a RS-232 serial management port on the faceplate. This port can be used to
manage the Base and Fabric. See Section 4.4, “Serial Select” on page 4-8 for
information about how to switch between managing the Base and the Fabric.
1.7 RTM Airflows
1.7.1 RTM Airflow Requirements
The following chart provides the RTM airflow requirements. No alarms are triggered
at any of the listed temperatures for the given airflow.
TABLE 1-2 Airflow Requirements
Watts m
3
/min CFM
Power Level
25˚C 28˚C 40˚C 55˚C 25˚C 28˚C 40˚C 55˚C
25 0.07 0.07 0.14 0.14 2.5 2.5 5 5