Sun Microsystems CP3240 Switch User Manual


 
1-12 Sun Netra CP3240 Switch Installation Guide September 2009
FIGURE 1-7 Injector/Ejector on the Switch (Open Position)
3. Disconnect all cables connected to the switch.
4. Loosen the two board retention screws that fasten the board to the enclosure.
5. Open the ejectors fully, rotating the handles outward until the board disengages
from the midplane.
6. Slide the board evenly out of the enclosure.
7. Determine if you are going to replace the rear transition module.
If you are going to replace the rear transition module, go to “Removing a Rear
Transition Module for a Switch” on page 1-13.
If you are not going to replace the rear transition module, you must install a
replacement switch or a filler panel to maintain the enclosures shielding and
cooling performance. Refer to Section 1.8.2.2, “Installing a Switch” on page 1-14.
injector/ejector mechanism