Sun Microsystems CP3240 Switch User Manual


 
Chapter 3 Configuring Jumper Settings 3-5
3.1.8 P10(3-4) IPMC FWE
These are reserved and should be left configured for the default setting.
3.1.9 P11(1-2) Forced-Board Enable
This jumper controls whether the switch is forced on when it is powered up, or if the
IPMI subsystem controls the power up of the switch. Forcing power to the board is
not enough for the board to boot. The board could still be held in reset. Configre P11
(3-4) jumper setting as well to bring the board out of reset.
3.1.10 P11(3-4) IPMC Board Reset
This jumper configres the IPMI to send a reset signal that will reset the entire board
TABLE 3-9 P10 (3-4) IPMC FWE Reserved Jumper Settings
P10
(3-4) Default Function
ON
OFF Default Normal operation
TABLE 3-10 P11 (1-2) Forced-Board Enable Jumper Settings
P11
(1-2) Default Function
ON Force power on. Use this to run without a ShMC.
OFF Default IPMI controls power to the board.
TABLE 3-11 P11 (3-4) IPMC Board Reset Jumper Settings
P11
(3-4) Default Function
ON IPMI subsystem cannot reset the switch. Use this to run without a
ShMC.
OFF Default IPMI subsystem can reset the switch and hold it in reset.