Glossary
CLIP
One or more consecutive positive or negative full scale samples.
The actual number of consecutive samples that constitute a
CLIP may be adjusted through the Level Meters submenu; the
factory setting is one (1).
Copy
Output a session report via the rear-panel RS-232 port.
Frame Sync Err
Frame synchronization error between the input pair and the
reference, as a percentage of the digital audio frame.
MUTE
One or more consecutive zero samples. The actual number of
consecutive samples that constitute a MUTE may be adjusted
through the Level Meters submenu; the factory setting is ten (10).
nil
The measured signal level is lower than 90 dBFS
Session
A mode of instrument operation during which the digital audio
input signals are monitored, and signal data are collected.
Session Time
The time elapsed since the beginning of the current Session.
True Peak
The actual highest positive or negative audio sample value. True
Peaks will often be greater than the highest meter reading when