Tektronix 070-8811-08 Computer Monitor User Manual


 
Reference
764 Digital Audio Monitor User Manual
47
and
(sign) +
(
) 1
)
if
4fsń60
ȍ
n +0
(
L
n
R
n
)
is u 0
or
(sign) +
(
1
)
if
4fsń60
ȍ
n +0
(
L
n
R
n
)
is t 0
The actual correlation meter reading is the rolling average of the
last i sample blocks:
M +
C
1
) C
2
),...,) C
i
i
where i is determined by the Correlation Meter Speed setting in the
Phase Display submenu. Table 1 lists i—and the corresponding
averaging intervalfor each meter speed selection.
Table 1: Correlation meter speed averaging intervals
Speed
setting
i
Equivalent
interval (s)
Speed
setting
i
Equivalent
interval (s)
1 1 0.0167 11 180 3.0
2 2 0.0333 12 210 3.5
3 4 0.0667 13 240 4.0
4 8 0.1333 14 270 4.5
5 16 0.2667 15 300 5.0
6 32 0.5333 16 330 5.5
7 60 1.0 17 360 6.0
8 90 1.5 18 390 6.5
9 120 2.0 19 420 7.0