Tektronix 070-8811-08 Computer Monitor User Manual


 
Reference
764 Digital Audio Monitor User Manual
71
MENU Commands. Use the MENU commands listed in Table 19 to
make selections from the 764 on-screen menus. The menus need not
be visible on the display to change a setting with a MENU command.
SYNTAX: MENU:mnemonic:<number> (unrecognized
number returns "Out Of Range Error")
Table 19: Remote control MENU commands
Command Value = setting Submenu, item
MENU:? Lists the Menu commands
MENU:mnemonic:? Lists the command syntax for the
queried mnemonic and gives the
current setting
MENU:DISMODE:<02> 0=4 Channels
1=Ch 12 + Sum & Diff
2=Ch 34 + Sum & Diff
Level Meters, Display Mode
MENU:INTERP:<01> 0=ON
1=OFF
Level Meters, Interpolation
MENU:BALLIST:<02> 0=True Peak
1=PPM
2=Extended VU
Level Meters, Ballistics
MENU:PHTIME:<010> 0 to 10 seconds Level Meters, Peak Hold Time
MENU:PPGMLVL:<300> 30 to 0 dBFS Level Meters,
Peak Program Level
MENU:TESTLVL:<300> 30 to 0 dBFS Level Meters, Test Level
MENU:ZERODB:<02> 0=Dgt. Full Scale (dBFS)
1=Peak Program (dBr)
2=Test Level (dBr)
Level Meters, Set 0 dB Mark to
MENU:CLIP:<1100> 1 to 100 samples Level Meters, Consecutive FS
Samples for CLIP
MENU:MUTE:<0100> 0 to 100 samples Level Meters, Consecutive 0
Samples for MUTE
MENU:CMTIME:<130> 1 to 30 seconds Level Meters,
CLIP/MUTE Hold Time(sec)
MENU:IGVBIT:<01> 0=NO
1=YES
Level Meters, Ignore Validity Bit