Reference
58
764 Digital Audio Monitor User Manual
Serial Port Submenu
The Serial Port submenu contains items used for setting the serial
port parameters and controlling the content of the session report. The
items and choices are listed in Table 10 and explained in the
subsequent paragraphs.
Table 10: Serial Port submenu items
Item Choices Factory setting
Flow Control SOFTWARE; HARD-
WARE; BOTH; NONE
SOFTWARE
Baud Rate 38400; 19200; 9600;
2400
38400
Copy NO REPORT; SHORT
REPORT; LONG RE-
PORT
NO REPORT
Peak Reading Interval
(sec)
0, 1, 2, ..., 300 (seconds) 60
Flow Control. Scroll to the “Flow Control:” menu choice (by turning
the multi-function know) and then press the soft button that
corresponds to the appropriate type of flow control. If you do not
know which flow control is correct for your application, first try
HARDWARE when outputting a report to a printer, and SOFTWARE
when downloading a report to a personal computer.
Baud Rate. Scroll to the “Baud Rate:” menu choice and press the soft
button that corresponds to rate that is used by the receiving printer or
PC. For fastest data transfer when outputting a session report to a PC,
select the highest baud rate available in both the 764 and the PC;
then, if you experience difficulty with flow control between the 764
and the PC, set both to the next lower baud rate available and try
again.
Copy. The Copy submenu item determines the type of report that is
output when you press the Copy soft button (see Figure 23). When
NO REPORT is selected, the “Copy” function is removed from the
third soft button, and you cannot output a Session Report.