4 Replacement Procedures 4.18 Fluorescent Lamp
Removing the board assembly, tape pad, sheets, light guide, bottom cover (B), and lamp
assembly
1. Remove the board assembly (Board Ass’y) (1). Perform this work in a clean room
and be careful not to scratch or get dirt on the polarized plate and B/L assembly.
2. Remove the tape pad (Tape Pad) fixing the sheets (2).
3. Remove the sheets and light guide (Sheets&LGP) (3). Be careful not to scratch or get
dirt on the sheets.
4. Remove the screws and bottom cover (B) (4). The screw tightening torque is
2.0kgf.cm maximum.
5. Remove the low voltage cable from the mold frame, then remove the lamp assembly
from the mold frame (5). Be careful not to apply excessive force. Do not leave any
dirt or double-sided tape glue on the mold frame.
Figure 4-85 Replacing 14.1 Inch LG.Philips fluorescent lamp (4)
4-96 Satellite A10/TECRA A1/Satellite Pro A10 Maintenance Manual (960-445)