Toshiba BSA4TMGS12QMR Label Maker User Manual


 
3.MAIN UNIT REPLACEMENT
EO18-33016A
3.4 Stepping Motor and Top Cover Open Sensor (Left)
3- 8
3.4 Stepping Motor and Top Cover Open Sensor (Left)
1. Remove the Side Panel from the printer. (Refer to Section 3.2.)
2. Remove the Platen Ass’y. (Refer to Section 3.3.)
3. Open the Top Cover and remove the screw which secures the Stepping Motor Frame.
4. Remove the screw to detach the Platen Gear Frame.
5. Remove the Platen Pulley Spacer together with the Platen Gear Frame.
6. Disconnect the Top Cover Open Sensor Cable.
NOTE: The Platen Pulley Spacer can be attached in either orientation.
SMW-3x6 Screw
Top Cover Open Sensor (Left)
SMW-3x6 Screw
Platen Gear Frame
Platen Pulley Spacer