Data Ports
Applicator Interface Connector
184
13383L-004 Rev. A XiIIIPlus/R110Xi/R170Xi User Guide 9/6/07
5 PAUSE Input To toggle the current Pause state, this input must be
asserted LOW for 200 milliseconds, or until the
SERVICE REQUIRED output (pin 10) changes state.
6 REPRINT Input • If the Reprint feature is enabled, this input must be
asserted LOW to cause the printer to reprint the last
label.
• If the Reprint feature is disabled, this input is ignored.
7+28V
(For the 5V board,
+28V is fused at 2 A.
For the 24–28V
board, +28V is fused
at 500 mA.)
Caution • Replace
the fuse only with
one of the same
type and rating.
Power The Interface Power Supply. Supplies power to external
sensors as required.
Note • If operating with 28V signals only, pin 7
may be used to supply power to pin 2, which
creates a non-isolated mode of operation. (This is
applicable for all printers except the
110XiIIIPlus.)
8 POWER GROUND
(+28 V DC Return)
Ground The Interface Power Ground.
Note • If pin 7 is used to supply power to pin 2,
use this pin to ground pin 1. (This is applicable for
all printers except the 110XiIIIPlus.)
9 — — No function.
10 SERVICE
REQUIRED
Output Asserted LOW in the following circumstances:
• the printhead is open
• the ribbon or media is out
• the printer is paused
• an operational fault occurs
• a Resynch error occurs while the applicator Resynch
mode is set to Error mode (see Select Resynch Mode
on page 96)
Table 22 • Applicator Interface Connector Pin Configuration (Continued)
Pin
No.
Signal Name Signal Type Description
* Applicator boards have separate part numbers for the +5V version (49872-099M) and the +24-28V version (33361-099M).