Zebra Technologies 2207A10L010 Label Maker User Manual


 
Operations
Adjust Media Sensors
58
13383L-004 Rev. A XiIIIPlus/R110Xi/R170Xi User Guide 9/6/07
Adjust Media Sensors
The transmissive sensor consists of two sections: a light source (the lower media sensor) and a
light sensor (the upper media sensor). The media passes between the two.
Adjust these sensors only when the printer cannot detect the top of the label. The control panel
LCD displays
ERROR CONDITION PAPER OUT, even though there are labels loaded in
the printer.
Upper Media Sensor—Inside Half of Media
To adjust the upper media sensor for the inside half of the media, complete
these steps:
1. Remove the ribbon (if ribbon is used).
2. See Figure 12. Locate the upper media sensor. The upper media sensor eye is directly
below the adjustment screw head.
Figure 12 • Upper Media Sensor Location
3. Using a Phillips-head screwdriver, slightly loosen the upper media sensor adjustment
screw.
Note • For most models of XiIIIPlus, the upper media sensor can be positioned along the
inside half of the media (the side closest to the back frame of the printer) or the outside half
of the media (the side farthest from the back frame of the printer). However, for the
220XiIIIPlus, you cannot move the sensors to the outside half of the media.
1
Upper media sensor adjustment screw
2
Upper media sensor
3
Printer back frame
1
2 3