10
Figure 4: Charging the P4T Series Battery with the LI72 Single Charger
Charging Battery Packs with the AT18737-xx LI72 Single Charger
Plug the LI72 into the appropriate AC wall receptacle, then insert the charge cable into the battery pack charger jack.
The amber/green charge indicator LED will indicate the status of the charger as per the following table.
LED Status Charger Status
Green Solid Fully Charged
Amber Solid Charging
Amber Blinking
Battery Contact Problem
1. Short Circuit of Output Terminals
2. Detection of Short Battery's Circuit
3. No Contact + Terminal
Over Voltage Protection
Over Current Protection
Temperature Waiting Time
Operating Temperature 0 to 40
o
C @ 30-85% Relative Humidity
Storage Temperature -30 to 60
o
C @ 10-90% Relative Humidity
Input Voltage AC100 to 240V 47 to 63Hz
Input Current 0.18A MAX
Output DC 8.4V 800mA