Charging the P4T Series Battery with the UCLI72-4 Quad Charger
The UCLI72-4 Quad Charger is designed to
charge up to four battery packs simultane-
ously. Charging times are as follows:
Battery Status Charging Time
80% charged 2.5 Hrs.
Full charge 5 Hrs.
• Ensure that the charger has been installed
properly per the Quad Charger instruction
manual. Ensure that the power indicator on
the front panel is on.
• Remove any protective shrink-wrap and
labels from all battery packs prior to first use.
Plug a battery pack into any one of the four
charging bays as shown opposite in Figure _,
noting the orientation of the battery pack.
Slide the battery pack into the charging
bay until it stops.
• Rock the battery pack back until it snaps
into place.
The amber indicator directly under the bat-
tery being charged will turn on if the battery
is properly inserted.
The indicators under each battery will allow
you to monitor the charging process per the
table below:
Amber Green
Battery Status
On O Charging
On Flashing
80% charged
(O.K. to use)
O On
Completely
Charged
Flashing O Faulty Battery
Section Continues
Important • A fault condition (flashing amber indicator) is caused by a problem with the battery
pack. The charger may indicate a fault because the battery is too hot or too cold to charge
reliably. Try to charge the battery again when it returns to the room’s ambient temperature.
If the amber indicator starts flashing on the second charging attempt, the battery should
be discarded. Always dispose of batteries in a proper manner. Refer to Appendix E of this
manual.
Fault
Fast Charge
Fault
Fast Charge
Fault
Fast Charge
Ready
Power
Full Charge
Ready
Full Charge
Ready
Full Charge
Full Charge
Fault
Fast Charge
Ready
Figure 5- UCLI72-4 Quad Charger
Notes: For more information regarding the installation and use of the UCLI72-4 Quad Charger refer to the instructions included
with the product.
The UCLI72-4 Quad Charger has a safety feature which stops charging a battery after six hours regardless of its charge state.
Charger
Bay
Amber
Indicator
Green
Indicator
Power Indicator
Power Supply
Slide Battery Pack
into a Charger bay
Rock Battery
Pack into place
Printer Preparation
pg. 7
Connecting the
Printer pg. 27
Radio Regulatory
Information pg. 31
RP4T Printers pg.
35
Maintenance pg. 36
Troubleshooting pg.
38
Specications pg.
43
Appendices pg. 46 Index pg. 52
P4T Overview-
pg. 5
Manual
Introduction pg. 4