A SERVICE OF

logo

4 Switch Interface Administration Digital Interfaces
UCS 1000 R4.2 Administration 585-313-507 Issue 3 April 2000 190
START DIAL SIGNALING PROVIDED BY CPE: WK
START DIAL SIGNALING PROVIDED TO CPE: WK (senderized
operation)
CPE DOES NOT SUPPORT DIFFERENT SIGNALING
BIDIRECTIONALLY
NUMBER OF DIGITS OUTPULSED TO CPE: This number should
match the number selected in the Maximum Digits in Called
Number E1/T1 option
THE CPE CAN ACCEPT O AS THE FIRST DIGIT
GLARE CONTROL: CPE WILL YIELD (WILL RELEASE)
DIRECT INWARD DIAL (DID): N
PBX ANSWER SUPERVISION WITHHELD: N
NETWORK AUTHORIZATION CODES: N
FRAME FORMAT: D4
IS PBX SENDERIZED: YES
CPE TIMING CAPABILITY: loop timed
SOURCE OF SYNCHRONIZATION PROVIDED BY CPE: NONE
SOURCE OF AUDIBLE RINGING ON CALLS TO CPE: PBX (CPE)