NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 1003
Outgoing Trunk Queuing - CCIS O-12
Programming (cont’d)
System 2, Index 4, Bit 0: Call Back and OG Trunk Queuing access code. 0/1 = Separate/Common.
Bit 1: Automatic setting of OG Trunk Queuing by On-Hook. 0/1 = Not Required/Required.
Note: 0=SHF+AccessCode.
System 3, Index 3, Bit 5: 3-Burst on the time above Ringer Patter. 0/1 = Not Required/Required.
System 3, Index 7: Assign OGQ Ring Back Pattern.
STEP 2: ANPD - Assign minimum necessary number of digits for the first number of the OGQ access codes.
STEP 3: ASPA - Assign the OGQ access codes.
To set: CI = B (Busy), SRV = SSC (Service Code), SID = 19
To cancel: CI = N (Normal), SRV = SSC (Service Code), SID = 20
STEP 4: ARTD - Assign the OGQ service for each route except the CCIS route.
9:TQ = 1: OGQ in service
STEP 5: ASFC - Allows Outgoing Queuing (SFI = 1) to the SFC of the stations.