NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 419
Internal Zone Paging I-21
Service Conditions
1. The number of Internal Zone Paging groups is a maximum of 99 groups for each tenant.
2. Each D
term
can be a member of multiple Internal Zone Paging groups.
3. A maximum of 255 groups per system can be simultaneously paged using this feature.
4. This feature is activated to idle stations in an Internal Zone Paging group.
5. When all INTERNAL ZONE PAGING groups are busy, Busy Tone is sent.
6. This service is not available from the Attendant Console, Central Office and Tie Line.
7. If all D
term
s in the designated group are unavailable, a Busy Tone will be sent.
8. When originating a call (or answering an incoming call) from a multi (sub) line on the D
term
called by
INTERNAL ZONE PAGING, the voice call to the prime line stops and becomes idle, and the path on the
multi line is established. Even if the call is completed, the voice call is not established again.
9. When a user cancels this feature with a held call, the user is recalled.
10. A maximum number of 24 D
term
s can be set this feature in a group.
11. A maximum of four stations is allowed INTERNAL ZONE PAGING in a Group of LEN (Level0-Level7).
12. If a station in the paged group is busy when the INTERNAL ZONE PAGING call is originated, the station
is not called/recalled even if the station becomes idle later.
13. After a station in the paged group answers the INTERNAL ZONE PAGING call, ringing at the other
member stations stop and two-way conversation starts.
14. While member stations are paged by INTERNAL ZONE PAGING call, the prime lines of stations in the
group are busy status. Thus, the stations cannot be received another call from station, tie line, C.O. line or
Attendant Consoles during paging.
15. When a prime line of a station in the paged group is a sub line of another D
term
, the sub line assigned to
another D
term
cannot be affected by the INTERNAL ZONE PAGING call (the sub line key does not flash
or light).
16. To use this feature, either the PA-16ELCJ or the PA-16ELCJ-B circuit cards is required.
17. This feature is not available for the IMG HDS Release IIIA, IV, and V software.
18. The user can page any INTERNAL ZONE PAGING groups in the FCCS network via FCCS link using
this feature.
19. An Internal Zone Paging group can consist of the D
term
stations accommodated in the same node. (The
group cannot be comprised of the D
term
s in different nodes.)
20. The maximum number of INTERNAL ZONE PAGING group per FCCS network is 255 groups.
FCCS
PBX
NE C
NEC
NE C
NEC
NEC
NEC
term
D
term
D
term
D
term
D
IZP Group A
PBX
term
D
/Analog Station
term
D
/Analog Station
IZP Group B