Call Back - D
term
C-1D
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Note 1
STEP 1: ANPDL - Reserve a number level for service feature access and cancel. Assign for Normal (N) and
Busy (B). Assign NND in accordance with a predetermined numbering plan.
STEP 2: ASPAL - Assign an access code to CALL BACK - Entry, SRV = SSC (Service Code), SID = 3 and a
Connection Status Index (CI) for Busy (B) service. For CALL BACK - Cancel, SRV = SSC (Service
Code), SID = 6. Assign a Connection Status Index (CI) for Normal (N) service.
Note 1: When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.