Call Forwarding-Intercept / Announcement C-25
FCCS Programming (contd)
1 = Connection is held until the station is released. See the requirements of the application for
the announcement equipment. For Dead level applications, assign data 0.
R: Sending RBT
0/1 = Yes/No
A: Answer Signal Sending (Answer from the incoming trunk)
0 = No/Yes Normally assign data 1.
M: Multiple Connection
0/1 = Single Connection/Multiple Connection
LGRT: Logical Route Number
TK: Trunk Number *Not necessary for M=1
STEP 3: ARRCN - This data must be assigned to the NCN.
Release the restriction between the terminating trunk and the announcement trunk.
STEP 4: ARSCN - This data must be assigned to the NCN.
Release the restriction between the announcement trunk and the station.