NEAX2400 IPX Feature Programming Manual
Page 322 NDA-24297, Issue 1
D-149 Direct Station Selection (DSS) Console
Programming (contd)
Add-On Module
This section explains how to assign an Add-On Module. The associated data programming is
explained in the following example:
Data Programming Procedure for Add-On Module
When assigning Add-On Module data, perform the following procedure. Note that X indicates the
value should be tailored to the existing system.
STEP 1: Assign a D
term
to an even-numbered LEN level. (In this example, LV 0is used.) Assign the Add-On
Module to the subsequent odd-numbered LEN level. (In this example LV 1is used.)
TN: X
STN: 201
LEN: 000101 odd-numbered LEN level
TEC: 12 fixed
RSC: X
SFC: X
STEP 2: Assign Line/Feature access keys to the Add-On Module. The upper 24 Line/Feature access keys
belong to the associated D
term
and the remaining lower 36 Line/Feature access keys belong to the Add-
on Module. Assignment of the D
term
and first 24 keys on the ADM: For assigning these keys
information, the associated D
term
port is used.
TN: X
STN: 200
TERMINAL LINE EQUIPMENT NUMBER (LEN) STATION NUMBER (STN)
Add-On Module 000101 201 Note
D
term
000100 200
LV
7
6
5
4
3
2
1
0
Note: Station number 201 is used only for assigning Line/Feature access keys to the Add-On Module.
Accordingly, these numbers are not used when operating the Add-On Module.
00 0504030201
54 5958575655
48 5352515049
42 4746454443
36 4140393837
30 3534333231
24 2928272625
18 2322212019
12 1716151413
06 1110090807
1 2 3
4 5 6
7 8 9
0 #
In this example an Add-On Module and the associated D
term
are assigned as follows:
D
term
(STN 200)
Add-On Module
ELC
n + 1
n