3Com 3C389 Network Card User Manual


 
Running the Diagnostics Program 5-9
The testing process might run as long as three minutes
and can be exited at any time by pressing [Enter] or by
removing the diskette and pressing [Esc]. Pressing [Esc]
will cause the computer to reboot. Pressing [Enter] will
end the test in progress and allow the user to select
another test option.
1 Boot the PC with TokenDisk diskette #1.
TokenDisk diskette #1 is a PC DOS system diskette.
2 At the DOS Menu, select 2, 3Com TokenLink Velocity
PC Card Extended Diagnostics.
3 Follow the instructions as they appear.
You will be prompted to select a test option. See “Test
Options” for descriptions.
Test Options
There are two test options: the wrap test and the
on-ring test.
The wrap test ensures that the PC Card and cable
hardware are functioning properly. For this test, connect
the NIC and cable to the network to perform a wrap test
through the hub or concentrator, or insert a wrap plug
(no wrap plug is required if you have a shielded twisted
pair cable connection) to help isolate a failure to the
NIC, the cable, or the wiring to the hub or concentrator.
The on-ring test verifies communication between the NIC
and the LAN. This test requires that the NIC is connected
to a network with other NICs, so the ring speed of the
network can be automatically sensed. If the NIC under
test is the only one on the network, the on-ring test will
fail. Continue testing the NIC using the wrap test, or
connect the NIC to a network that has at least one other
station connected and open.