Accton Technology ES4548D Switch User Manual


 
Renumbering the Stack
4-7
4
Renumbering the Stack
If the units are no longer numbered sequentially after several topology changes or
failures, you can reset the unit numbers using the “Renumbering” command. Just
remember to save the new configuration settings to a startup configuration file prior
to powering off the stack Master.
Note: This switch does not support stacking.
Command Usage
The startup configuration file maps configuration settings to each switch in the
stack based on the unit identification number. You should therefore remember to
save the current configuration after renumbering the stack.
For a line topology, the stack is numbered from top to bottom, with the first unit in
the stack designated at unit 1. For a ring topology, the Master unit taken as the top
of the stack and is numbered as unit 1, and all other units are numbered
sequentially down through the ring.
Web – Click System, Renumbering.
Figure 4-5 Renumbering the Stack
CLI – This example renumbers all units in the stack.
Resetting the System
Web – Click System, Reset. Click the Reset button to restart the switch. When
prompted, confirm that you want reset the switch.
Figure 4-6 Resetting the System
CLI – Use the reload command to restart the switch.
Note:
When restarting the system, it will always run the Power-On Self-Test.
Console#switch all renumber 34-2
Console#
Console#reload 34-2
System will be restarted, continue <y/n>?