Alcatel Carrier Internetworking Solutions omniswitch Switch User Manual


 
Using SNMP Quick Steps for Setting Up Trap Filters
OmniSwitch 6600 Family Switch Management Guide March 2005 page 10-5
Filtering by Individual Traps
The following example enables trap filtering for the coldstart, warmstart, linkup, and linkdown traps. The
identification numbers for these traps are 0, 1, 2, and 3. When trap filtering is enabled, these traps will be
filtered. This means that the switch will not pass them through to the SNMP management station. All
other traps will be passed through.
1 Specify the IP address for the SNMP management station and the trap identification numbers.
-> show snmp trap filter 210.1.2.1 0 1 2 3
Note. Optional. You can verify which traps will not pass through the filter by entering the snmp trap
filter command. The display is similar to the one shown here:
-> show snmp trap filter
ipAddress trapId list
-----------------+----------------------------------------
210.1.2.1 0 1 2 3
The SNMP management station with the IP address of 210.1.2.1 will not receive trap numbers 0, 1, 2,
and 3.
For trap numbers refer to the “SNMP Traps Table” on page 10-9. For more information on the CLI
commands and the displays in these examples, refer to the OmniSwitch CLI Reference Guide.