Alcatel Carrier Internetworking Solutions omniswitch Switch User Manual


 
Using SNMP SNMP Overview
OmniSwitch 6600 Family Switch Management Guide March 2005 page 10-21
47 pethPsePortOnOffNotification pethPsePortDe-
tectionStatus
module Indicates if power inline port is
or is not delivering power to the a
power inline device.
pethPsePortDetectionStatus—Describes the operational status of the port PD detection. A value of dis-
abled(1)- indicates that the PSE State diagram is in the state IDLE. A value of searching(2)- indicates that the
PSE State diagram is in the state DETECTION, CLASSIFICATION, SIGNATURE_INVALID or BACKOFF.
A value of deliveringPower(4) - indicates that the PSE State diagram is in the state POWER_UP, POWER_ON
or POWER_OFF. A value of fault(5) - indicates that the PSE State diagram is in the state TEST_ERROR or the
state IDLE due to the variable error condition. Faults detected are vendor specific. A value of test(7) - indicates
that the PSE State diagram is in the state TEST_MODE. A value of denyLowPriority(8) indicates that the port
was disabled by the power management system, in order to keep active higher priority ports.
Note: This trap is not supported on OmniSwitch 6600 Family switches in the current release.
48 pethPsePortPowerMaintenanceStatus-
Notification
pethPsePort-
PowerMain-
tenanceStatus
module Indicates the status of the power
maintenance signature for inline
power.
pethPsePortPowerMaintenanceStatus—The value ok(1) indicates the Power Maintenance Signature is
present and the overcurrent condition has not been detected. The value overCurrent (2) indicates an overcurrent
condition has been detected. The value mPSAbsent(3) indicates that the Power Maintenance Signature is
absent.
Note: This trap is not supported on OmniSwitch 6600 Family switches in the current release.
49 pethMainPowerUsageOnNotification pethMainPseC-
onsumption-
Power
module Indicates that the power inline
usage is above the threshold.
pethMainPseConsumptionPower—Measured usage power expressed in Watts.
Note: This trap is not supported on OmniSwitch 6600 Family in the current release.
50 pethMainPowerUsageOffNotification pethMainPseC-
onsumption-
Power
module Indicates that the power inline
usage is below the threshold.
pethMainPseConsumptionPower—Measured usage power expressed in Watts.
Note: This trap is not supported on OmniSwitch 6600 Family in the current release.
51 ospfNbrStateChange ospfRouterId
ospfNbrIpAddr
ospfNbrAd-
dressLessIn-
dex
ospfNbrRtrId
ospfNbrState
ospf Indicates a state change of the
neighbor relationship.
ospfRouterId—A 32-bit integer uniquely identifying the router in the Autonomous System. By convention, to
ensure uniqueness, this should default to the value of one of the router’s IP interface addresses.
ospfNbrIpAddr—The IP address this neighbor is using in its IP Source Address. Note that, on address-less
links, this will not be 0.0.0.0, but the address of another of the neighbor’s interfaces.
ospfNbrAddressLessIndex—On an interface having an IP Address, zero. On address-less interfaces, the cor-
responding value of ifIndex in the Internet Standard MIB. On row creation, this can be derived from the
instance.
ospfNbrRtrId—A 32-bit integer (represented as a type IpAddress) uniquely identifying the neighboring router
in the Autonomous System.
ospfNbrState—The State of the relationship with this Neighbor.
No. Trap Name Objects Family Description