Alcatel Carrier Internetworking Solutions omniswitch Switch User Manual


 
SNMP Overview Using SNMP
page 10-22 OmniSwitch 6600 Family Switch Management Guide March 2005
52 ospfVirtNbrStateChange ospfRouterId
ospfVirtN-
brArea
ospfVirtN-
brRtrId
ospfVirtN-
brState
ospf Indicates a state change of the
virtual neighbor relationship.
ospfRouterId—A 32-bit integer uniquely identifying the router in the Autonomous System. By convention, to
ensure uniqueness, this should default to the value of one of the router's IP interface addresses.
ospfVirtNbrArea—The Transit Area Identifier.
ospfVirtNbrRtrId—A 32-bit integer uniquely identifying the neighboring router in the Autonomous System.
ospfVirtNbrState—The state of the Virtual Neighbor Relationship.
53 httpServerDoSAttackTrap httpConnection-
Stats
httpsConnec-
tionStats
webmgt This trap is sent to management
station(s) when the HTTP server
is under Denial of Service attack.
The HTTP and HTTPS connec-
tions are sampled at a 15 second
interval. This trap is sent every 1
minute while the HTTP server
detects it is under attack.
httpConnectionStats—The number of HTTP connection attempts over the past 15 seconds.
httpsConnectionStats
The number of HTTPS connection attempts over the past 15 seconds.
54 alaStackMgrDuplicateRoleTrap alaStack-
MgrSlotNI-
Number
alaStackMgr-
ChasRole
chassis The element identified by
alaStackMgrSlotNINumber
detected the presence of two ele-
ments with the same primary or
secondary role as specified by
alaStackMgrChasRole on the
stack.
alaStackMgrSlotNINumber—Numbers allocated for the stack NIs as follows:
- 0: invalid slot number
- 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
- 1001..1008: switches operating in pass through mode
- 255: unassigned slot number.
alaStackMgrChasRole—The current role of the chassis as follows:
- unassigned(0),
- primary(1),
- secondary(2),
- idle(3),
- standalone(4),
- passthrough(5).
55 alaStackMgrClearedSlotTrap alaStack-
MgrSlotNI-
Number
chassis The element identified by
alaStackMgrSlotNINumber will
enter the pass through mode
because its operational slot was
cleared with immediate effect.
alaStackMgrSlotNINumber—Numbers allocated for the stack NIs as follows:
- 0: invalid slot number
- 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
- 1001..1008: switches operating in pass through mode
- 255: unassigned slot number.
Note: This trap is not supported on OmniSwitch 6600 Family switches.
No. Trap Name Objects Family Description