AMX NXD-700Vi Computer Monitor User Manual


 
Appendix C: Troubleshooting
206
7" Modero Widescreen Touch Panels
Troubleshooting Information (Cont.)
Symptom Solution
My WEP doesn’t seem to be
working.
WEP will not work unless the same default key is set on both the
panel and the Access Point.
For example: if you had your access point set to default key 4 (which
was 01:02:03:04:05) you must also set the Modero’s panel key 4 to
01:02:03:04:05.
NetLinx Studio only detects one of
my connected Masters.
Each Master is give a Device Address of 00000.
Only one Master can be assigned to a particular System number. If
you want to work with multiple Masters, open different instances of
NetLinx Studio and assign each Master its own System value.
Example: a site has an NXC-ME260/64 and an NI-4000. In order to
work with both units. The ME260/64 can be assigned System #1 and
the NI-4000 can then be assigned System #2 using two open
sessions of NetLinx Studio 2.
I can’t seem to connect to a
NetLinx Master using my NetLinx
Studio 2.x application.
From the Settings > Master Comm Settings > Communication
Settings > Settings (for TCP/IP), uncheck the "Automatically Ping
the Master Controller to ensure availability".
The pinging is to determine if the Master is available, and to reply
with a connection failure instantly if it is not. Without using the ping
feature, you will still attempt to make a connection, but a failure will
take longer to be recognized. Some firewalls and networks do not
allow pinging, though, and the ping will then always result in a failure.
When connecting to a NetLinx Master controller via TCP/IP, the
program will first try to ping the controller before attempting a
connection. Pinging a device is relatively fast and will determine if the
device is off-line, or if the TCP/IP address that was entered was
incorrect. If you decide NOT to ping for availability and the controller
is off-line, or you have an incorrect TCP/IP address, the program will
try for 30-45 seconds to establish a connection.
Note: If you are trying to connect to a master controller that is behind a
firewall, you may have to uncheck this option. Most firewalls will not
allow ping requests to pass through for security reasons.