Asante Technologies 8000 Switch User Manual


 
Configuration
Page 3-46
Current Options
Table 3-12 describes the settings shown in the System Reset Configuration
Menu.
Table 3-12 System Reset Configuration options
Resetting the IntraCore 8000
To reset the IntraCore 8000, use the following procedure.
1 Open the System Reset Menu by typing r in the Configu-
ration Menu.
2 Type r, d or i. Typing r resets the IntraCore 8000. Typing
d resets the IntraCore 8000 to the factory default. Typing i
resets the IntraCore 8000 to the factory default without
affecting its IP and Bootstrap configuration.
3 Type y to confirm the reset or type n to cancel the reset.
K Note: During the scheduled reset operation, you can
see the reset countdown decrement by refreshing the
screen.
Option Description
Schedule Reset Time Number of seconds until the scheduled reset.
Cancel Reset Stops the scheduled reset.
Reset Switch Performs a warm reboot to reset the IntraCore 8000 immedi-
ately.
Reset Switch to Factory
Default
Resets the IntraCore 8000 to the original factory settings.
Reset Switch to Factory
Default except IP &
Bootstrap
Resets the IntraCore 8000 to the original factory settings with-
out modifying the IP and Bootstrap configuration.