Asus TS300-E5 Server User Manual


 
6-46
Chapter 6: RAID conguration
8. Repeat steps 5 and 6 to add the second disk to the volume.
9. When done, press <C> to create the array, then select Save changes then
exit this menu.
10. The utility creates the array.
7. A conrmation screen appears.
Press <M> to keep existing data on the rst disk. If you choose this option,
data on the rst disk will be mirrored on the second disk that you will add to
the volume later. Make sure the data you want to mirror is on the rst disk.
Press <D> to overwrite any data and create the new IM array.
Esc=ExitMenuF1/Shift+1=Help
Space/+/-=SelectdiskforarrayorhotspareC=Createarray
LSICorpCongUtilityv6.20.00.00(2007.12.04)
Create New Array -- SAS1064E
M -Keepexistingdata,migratetoanIMarray.
Synchronizationofdiskwilloccur.
D -Overwriteexistingdata,createanewIMarray.
ALLDATAonALLdiskinthearraywillbeDELETED!!
No Synchronization performed.
Createandsavenewarray?
CancelExit
Savechangesthenexitthismenu
Discardchangesthenexitthismenu
ExittheCongurationUtilityandReboot
LSICorpCongUtilityv6.20.00.00(2007.12.04)
Processing...maytakeupto1minute
Creating RAID array...