Video Dynasync
The Video Dynasync command allows you to set EDID settings. Use the
Formula - to set Parameters - to create a Command.
Formulas:
Command + Control + [Enter]
Parameters:
Video Dynasync Commands
Some available formulas for Video Dynasync commands are as follows:
1. Command + Control + [Enter]
For example, to set the default EDID setting, type the following:
vds default [Enter]
2. Command + Control + [Enter]
For example, to enable EDID detection, type the following:
vds on [Enter]
Note: Each command string can be separated with a space.
Command Description
vds Video Dynasync Command
Control Description
default Set the default EDID
reload A trigger to force the switch to reload the
EDID from the connected display
off Disable the EDID reflash function, pass-
through EDID from previous connected
display or use default EDID
on The device will enable EDID detection from
the connected display every 3 secs after it is
powered on
Enter Description
Enter Enter and send out command