ATTO Technology V-Class Network Card User Manual


 
90
Hot swap spare sled
To set up two RAID Level 5 groups with Hot
Spare sleds
1 Connect to Diamond Storage Array services
(refer to
Accessing the Array
on page 17) and use
the CLI or enter ATTO ExpressNAV
Advanced
CLI Configuration page.
2Type
set QuickRAID5 2 2
3Type SaveConfiguration Restart
The Diamond is configured into two RAID Level
5 groups with two Hot Spare sleds.
Exhibit 9.2-1 Configuration of sleds in RAID Level 1: five LUNs with two Hot Spare sleds
Exhibit 9.2-2 Configuration of sleds in RAID Level 10: five mirrored pairs of sleds in one Virtual Drive and two Hot
Spare non-mirrored sleds
Exhibit 9.2-3 Configuration of sleds in RAID Level 5
Sled123456789101112
Drive12121212121212121212121
2
QuickRAID5
1
LUN 1
Hot
Spare
QuickRAID5
2
LUN 1 LUN 2
Hot
Spare
Hot
Spare
1 Virtual Drive
2 Hot Spare sleds