ATTO Technology V-Class Network Card User Manual


 
76
Update firmware
4 Copy the latest array image file, “...”.ima, onto
the host computer and note its directory such
as
c:\diamond\flash\“...”.ima
5 First time use: Upon successful power up and
diagnostics, set the host computer with the
appropriate settings such as IP Address.
The host computer must have appropriate
network settings to allow it to communicate with
the array. Please see your system
administrator for more information.
6 Change directories to the place where you
copied the “...”.ima file such as
cd c:\diamond\flash
7 Open a FTP session using a user-defined IP
address. The IP address must be a valid
address for your network.
8 At the FTP login prompt, type
sysadmin as the
userID.
9 Press
return at the password prompt.
10 Type
put “...”.ima.
The array should acknowledge receiving the file
and display a message not to interrupt power
for 90 seconds.
CAUTIONCAUTION
Do not interrupt the flash process. If the
process is interrupted, the Diamond
Storage Array becomes inoperable and
must be returned to the factory for repair.
Do not turn off the Diamond Storage Array
until the display returns the Ready prompt.
If upgrading the firmware from versions
older than 2.5.3, follow the procedures
outlined in
Resetting Defaults
on page 83.
11 When the flash procedure is complete, cycle
power on the array.