ATTO Technology V-Class Network Card User Manual


 
24
Ethernet protocols
6Type SaveConfiguration restart to reboot the
array.
7 Install SNMP management software on each
client you wish to receive traps (messages).
8 Call technical support to get the appropriate
MIB file for your array.
9 For each client, copy the MIB file to the
directory containing the SNMP management
software.
10 From within the SNMP management software,
compile the file attodmnd-mib.mib according to
the software’s procedures.
11 Unload any default MIBs.
12 Load the Diamond MIB ATTODIAMOND.
13 When requested, enter the array’s IP address
as the Remote SNMP Agent.
14 The SNMP management software contacts the
agent in the array. The screen replies with
system information.
15 Status is monitored and reported through the
SNMP management software.
Traps are generated for the following situations:
Temperature status changes in any of the
sensors located on the array mid-plane.
A drive or a sled is physically removed from the
Array or put into the Array.
The power supply is turned on or off.
The fan is physically stopped.