ATTO Technology V-Class Network Card User Manual


 
42
Diagnostic CLI commands
PartitionInfo
Displays Partition information for the selected partitions
or all partitions.
Get syntax: PartitionInfo [active|planned] [Virtual Drive
ID] [Partition ID]
RAID5ClearDataStatus
Displays the status of RAID5 Clear Data processing. S
represents the sled number, D represents the drive
number.
Choices: applies to RAID5 only
Set syntax: RAID5ClearDataStatus
RAIDRebuildStatus
Displays the RAID1, RAID 5 or RAID 10 Rebuild Status
Summary. If no RAID groups are defined, the header
information is displayed with no data. The status
summary contains the RAID1, RAID 5 or RAID 10.The
RAIDRebuildStatus command has no effect on the state
of any rebuild in progress.
Member index and the following fields in tabular form:
Status
: OK, DEGRADED, IN PROGRESS, or
FAULTED
Sled Number
: Location of the sled
Current LBA
: Logical block currently being
rebuilt
Maximum LBA:
Last logical block to be rebuilt
Status OK
: the RAID1 Mirror is in sync and no
rebuild activity is occurring. The Current LBA,
Maximum LBA and percentage complete values
are not displayed.
Status Degraded
: the RAID1 Mirror is out of sync
and is waiting to be rebuilt.
Status In Progress
: the RAID1 Mirror is out of sync
and a rebuild is occurring on the respective
drive.
Status Faulted
: the RAID1 Mirror is out of sync
and an error occurred in an attempt to
synchronize the drives in the RAID 1 group.
SerialNumber
View the serial board number, a 10-character field. The
first four alphanumeric characters are an abbreviation
representing the product name. The remaining six digits
are the individual unit’s number.
Get syntax: get SerialNumber
SledFaultLED
Changes the state of the selected sled LED to the
indicated state.
Choices: sled number 1-12 or all, turn on or off
Default: off
Set syntax: set SledFaultLED [ all | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9
|10 |11| 12] [ on | off]
SMARTData
Displays the current SMART Data (Self-Monitoring
Analysis and Reporting Technology) for the specified
drive.
Immediate command: SMARTData [Sled#] [Drive#]
Temperature
Returns the current internal temperature of this Diamond
Storage Array in degrees Celsius. The value is read only.
Get syntax: get Temperature
VirtualDriveInfo
Displays the named Virtual Drive definitions.
Get syntax: VirtualDriveInfo [active|planned] [Virtual
Drive ID]
ZoneInfo
Displays the named zones’ definitions. Information about
the Active Zone Configuration is the default; if you want
information about the Planned Zone Configuration, type
ZoneInfo Planned zone_name.
Zone syntax: ZoneInfo [Planned] [zone_name] [all]