Ambient Atmospheric Condition Ratings
Heat Dissipation 92 BTU/hr
Airflow 8 cfm
Temperature
32 to 104 degrees Fahrenheit (0 to 40 degrees Celsius) operating;
-4 to 158 degrees Fahrenheit (-20 to 70 degrees Celsius) nonoperating
Humidity 10 - 95% noncondensing
Safety and EMC Approvals
and Markings
UL, FCC, cUL, ICES-003, CE, GS, VCCI, MIC, C-Tick, GOST
Safety certifications and EMC certifications for this product are obtained under
one or more of the following designations: CMN (Certification Model Number),
MPN (Manufacturer’s Part Number) or Sales Level Model designation. The
designation that is referenced in the EMC and/or safety reports and certificates
are printed on the label applied to this product.
Table F.3: DSR1024 Switch Product Specifications
Server Ports
Number 1
Type PS/2, Sun, USB and Serial
Connectors 8-pin modular
Sync Types Separate horizontal and vertical
Plug and Play DDC2B
Video Resolution
640 x 480 @ 60 Hz
800 x 600 @ 75 Hz
960 x 700 @ 75 Hz
1024 x 768 @ 75 Hz
1280 x 1024 @ 75 Hz
Supported Cabling 4-pair UTP CAT 5 or CAT 6, 50 meters maximum length
Dimensions
Form Factor Desktop
Height x Width x Depth
1.10 x 8.08 x 6.30 in
(2.80 x 20.51 x 16.00 cm)
Weight (without cables) 1.1 lbs (0.50 kg)
Table F.2: DSR1021/1022 Switch Product Specifications (Continued)