Barco R90501005 Projector User Manual


 
13. Projector control
Image 13-50
When selecting DMX monitor and no DMX device is connected, the message “No DMX data, check connection
<ENTER> to display channels” appears on the screen. When ENTER is pressed the same window appears as
DMX Monitor but without values.
About motor control (channel 6 and 7)
If channel #6 is brought to 32 or more, this is the same as “motor” forward (as pushing the button on the side panel). It also disables
control of channel 7.
If channel #7 is brought to 32 or more, this is the same as “motor” reverse (as pushing the button on the side panel). It also disables
control of channel 6.
Both channels above 32 means no action.
Channel 6 and 7:
0 - 31 No action
31 - 255 Action start
About channel 4 and 5
Channel 4:
0 - 31 Input 1
32 - 63 Input 2
64 - 255 No image (pause)
Channel 5:
0-31 Off
32 - 63 Focus
64 - 95 Zoom
96 - 127 Horizontal shift
128 - 255 Vertical shift
13.6.4 DMX mode
What can be done ?
2 modes for DMX are available:
Basic which has currently 2 channels implemented.
Full which has currently 9 channels implemented and 10th free channel.
Depending on the DMX application the correct mode has to be selected.
For the complete DMX chart, see "DMX Chart", page 195.
How to set the mode
1. Press MENU to activate the menus.
2. Use the or key to select Projector control and press ENTER.
148
R59770021 CLM R10+ 11/10/2010