Barco R90501005 Projector User Manual


 
14. Service menu
Load custom settings
1. Connect a FAT 16 formatted USB device to the USB port.
2. Press MENU to activate the menus.
3. Use the or key to select Service and press ENTER.
The service window opens.
4. Use the or key to select USB memory and press ENTER.
5. Use the or key to select Load custom settings and press ENTER.
An list of serial numbers is given.
6. Use the or key to select the serial number to start from to load the settings.
The settings from the selected projector on the USB device are loaded into the current attached projector. The current projector
settings are overwritten with these settings. (image 14-52, image 14-53, image 14-54)
Image 14-52
Image 14-53
Image 14-54
14.9 Over temperature DMD safety
What can be done
When the temperature of the DMD becomes higher than the normal operation temperature (between 60 and 64 °C) it is possible to
switch the lamp mode of the projector automatically from 4 lamps to 2 lamps so that the DMD temperature can cool down. A warning
remains on the local LCD panel and the warning LED is on as long as the temperature is too high. When the temperature exceeds
64°C then the projector is switched to standby and an error is displayed on the LCD panel.
How to congure the over temperature safety
1. Press MENU to activate the menus.
2. Use the or key to select Service and press ENTER.
3. Use the or key to select Safety and press ENTER.
4. Use the or key to select Overtemp DMD and press ENTER to toggle between [On] and [Off].
On When temperature is too high, lamp mode is switched from 4 to 2 lamps. The 4 lamps mode can only be restored
after switching rst to standby and restarting the projector.
If the temperature exceeds 64 °C, the projector is switched to standby.
Off for a temperature between 60 and 64 °C the projector continues in normal operation but the warning is set on the
LCD display. Once the temperature is higher then 64 °C, then the projector is switched to standby.
The following text is displayed on the LCD: “DMD temperature to high. Please, check cooling liquid level ! Check
dust lters ! Press any key to conrm.”
See image 14-55, image 14-56, image 14-57.
164
R59770021 CLM R10+ 11/10/2010