Barco R90501005 Projector User Manual


 
E. Troubleshooting
Error
code
Description Error Warning
Caused by
Action
4198
FPGA PMP init
failed
Yes
-
6099 Board ID
unkown
version
Yes
6098 Board ID
invalid string
Yes
7999 DMD temp low Yes Yes Low temperature on DMD turning on the lamp(s) will heat up
the DMD
7998 DMD temp high Yes Yes High temperature on DMD
check if air slots are free, clean air
lters.
If problem persists, call a qualied
service engineer.
7997 Ambient temp
low
Yes Yes Ambient temperature out of
specications
take measurements to increase the
temperature
7996 Ambient temp
high
Yes Yes
Ambient temperature out of
specications
check ambient conditions
check if air slots are free, clean air
lter.
7995
TEC temp low
7994
TEC temp high
Yes Yes
7992
LPS1 temp
high
Yes Yes
High temperature on LPS1 check if air slots are free, clean air
lters.
If problem persists, call a qualied
service engineer.
7990
LPS2 temp
high
Yes Yes
High temperature on LPS2 check if air slots are free, clean air
lters.
If problem persists, call a qualied
service engineer.
7988
LPS3 temp
high
Yes Yes
High temperature on LPS3 check if air slots are free, clean air
lters.
If problem persists, call a qualied
service engineer.
7986 LPS4 temp
high
Yes Yes High temperature on LPS4 check if air slots are free, clean air
lters.
If problem persists, call a qualied
service engineer.
7978 Lamp4 temp
high
Yes Yes High temperature on lamp 4
check if air slots are free, clean air
lters.
If problem persists, call a qualied
service engineer.
7924 Fan radiator A
low
Yes Yes Fan is running too slow or not at all If problem persists, call a qualied
service engineer
7922 Fan radiator B
low
Yes Yes Fan is running too slow or not at all
If problem persists, call a qualied
service engineer
7920 Fan outlet A
low
Yes Yes Fan is running too slow or not at all
If problem persists, call a qualied
service engineer
7918 Fan outlet B
low
Yes Yes Fan is running too slow or not at all If problem persists, call a qualied
service engineer
7916 Fan power
supply A low
Yes Yes Fan is running too slow or not at all
If problem persists, call a qualied
service engineer
7914 Fan power
supply B low
Yes Yes Fan is running too slow or not at all
If problem persists, call a qualied
service engineer
7912 Fan LPS A low Yes Yes Fan is running too slow or not at all If problem persists, call a qualied
service engineer
7910
FanLPSBlow
Yes Yes Fan is running too slow or not at all
If problem persists, call a qualied
service engineer
204 R59770021 CLM R10+ 11/10/2010