Chapter 5: Local Management
Page 5-46 2H22-08R SmartSwitch 2208 User’s Guide
6. Use the arrow keys to highlight the SAVE command. Press ENTER.
The message “SAVED OK” displays and Local Management saves
the changes to memory.
5.11.4 Configuring an FE-100FX or FE-100F3
Interface for Port 7 or 8
When an FE-100FX or FE-100F3 is installed in port 7 or 8, it must be
manually set to operate in the same technology as the device at the other
end of the connected segment. Section 5.11.5 provides instructions for
manually setting the port with an FE-100FX or FE-100F3 interface.
5.11.5 Setting the FE-100FX and FE-100F3
in Operational Mode
Use this field to set the active technology. This field toggles between
100Base-FX and 100Base-FXFD (full duplex). To set the active
technology through Local Management, proceed as follows:
1. Use the arrow keys to highlight the Desired Operational Mode field.
2. Use the SPACE bar to select 100Base-FX or 100Base-FXFD (full
duplex).
3. Press ENTER. The port now operates in the chosen mode.
4. Use the arrow keys to highlight the SAVE command. Press ENTER.
The message “SAVED OK” displays and Local Management saves
the changes to memory.