Specifications
7-3
Appendix
7
Software Specifications
Operating environment
(Printer unit only)
Operating environment temperature: 7.5 to 32.5 °C (45.5 to
90.5 °F)
Humidity: 5 to 90 % RH (no condensation)
Storage environment
(Printer unit only)
Storage environment temperature: 0 to 35 °C (32 to 95 °F)
Humidity: 35 to 85 % RH (no condensation)
Host interface
USB interface
* USB Full-Speed (USB1.1 equivalent)
Power supply
120 V 50/60 Hz (± 2 Hz)
220 - 240 V (±10%) 50/60 Hz (± 2 Hz)
Power consumption
(at temperature of 20 °C or
68 °F)
120 V
Average during operation: approx. 350W
Average during standby: approx. 7W
220 - 240 V
Average during operation: approx. 360W
Average during standby: approx. 7W
Consumables
Toner
cartridge
Toner cartridge*
1
Printable pages: approx. 2500 pages*
2
*
1
Purchase a toner cartridge of the same product code
when you need it. (See p. 5-2.)
*
2
For A4 or Letter
Weight
120 V model
Printer unit ...approx. 6.5 kg (Excluding the toner cartridge)
Cassette........................................................approx. 0.9 kg
Toner cartridge..............................................approx. 0.7 kg
220-240 V model
Printer unit ...approx. 6.1 kg (Excluding the toner cartridge)
Cassette........................................................approx. 0.8 kg
Toner cartridge..............................................approx. 0.7 kg
Item Specifications
Printing software CAPT (Canon Advanced Printing Technology)
Printable area
Area excluding 5mm from the upper, lower, right and left
of the paper sides.