Cisco Systems 11500 Series Switch User Manual


 
C-7
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-03
Appendix C Troubleshooting
Troubleshooting the Boot Process
OffDM Verification of the Boot Configuration Record and Disk
During OffDM, the CSS checks the configuration record and initializes the disk.
The following sections discuss:
Errors in the Boot Configuration Record
Failure of the Disk Drive in the SCM
Errors in the Boot Configuration Record
If the CSS detects any errors in the configuration record, a failed message appears
along with information on the configuration parameter in question. The problems
may include a misconfigured IP and subnet address, or there is no primary or
secondary boot record. The CSS does not continue the boot process until the
problem is resolved.
If a failed message occurs:
1. Enter the OffDM menu and display your current configuration record. For
detailed information on using OffDM, refer to the Cisco Content Services
Switch Administration Guide.
2. Correct the misconfiguration.
3. Reboot the CSS.