Compaq 3000 Computer Accessories User Manual


 
RAID Array 3000 Storage Subsystem
EK–SMCPQ–UG. C014-10
Figure 4-9. Restored Configuration Example
NOTE
Restoring the configuration in the following step may
take up to 5 minutes. Be patient.
4.
Enter the file name that you saved in Section 4.2.1 and click on Restore.
4.2.7 Update Firmware on Second Controller
1. After configuration has been restored, update firmware on the second controller.
Repeat the procedure in Section 4.2.2.1 or 4.2.2.2.
2. After the configuration has been restored and firmware has been updated, power
down the system.
4.2.8 Install Original Controller
1. If installing option kit DS-HSZ22-AA, add the second SIMM to the original
controller. If installing option kit DS-HSZ22-AB, replace the existing SIMM
with the two remaining SIMMs supplied with the kit. (See Section 4.2.4 for in-
structions.)
2. Install the second controller into the controller shelf and power up the system.
The system is now in the dual-redundant operating mode.
3. Locate the second serial cable that came in the second controller kit. Connect
this cable to the second controller serial port on the RA3000 and to COM 2 port
and restart SWCC in serial mode. You now have two serial connections.
4.
To check that the controller pair is in redundant mode, click on the Controller
icon. Properties for both controllers should be visible. Firmware revision of
both controllers must be identical. If either controller is shown in gray, refer to
your RA3000 Getting Started Guide for more detailed instructions.