Dell 4300 Computer Hardware User Manual


 
Codes and Messages 3-15
3RZHUVXSSO\
GHWHFWHGD
IDLOXUH
In systems with
optional redundant
power supplies, the
power supply sensor
detected a failure in
one of the power
supplies. If possible,
the power supply
number is provided.
Check to see
whether the power
supply indicators
show a power sup-
ply failure. Make
sure that the latch
switch on each
power supply is
enabled. Make cer-
tain that each
connection to the
power source is
secure.
3RZHUVXSSO\
ORVWUHGXQ
GDQF\GHWHFWHG
In systems with
optional redundant
power supplies, the
system has detected
that it has lost power
supply redundancy. If
one (or another) of
the power supplies
fails, the system will
not be able to main-
tain operation. This
could be the result of
a failed power sup-
ply or too many
adapters installed in
the system.
Check to see
whether the power
supply indicators
show a power sup-
ply failure. Make
sure that the latch
switch on each
power supply is
enabled. Make
certain that each
connection to the
power source is
secure. This could
be a normal condi-
tion because the
default system
configuration is
nonredundant. The
system will function
normally in a
nonredundant
configuration.
7HPSHUDWXUH
VHQVRU
GHWHFWHGD
IDLOXUH
A temperature probe
on the backplane
board, system board,
or drive carrier in the
specified server has
exceeded its temper-
ature failure range. If
possible, the chassis
number and probe
number are provided.
Check for a fan fail-
ure. If needed,
replace the fan or
fan assembly.
7DEOH'HOO2SHQ0DQDJH+,3$OHUW/RJ0HVVDJHVFRQWLQXHG
0HVVDJH &DXVH &RUUHFWL YH$FWLRQ