Dell DL2000 Computer Drive User Manual


 
140 Troubleshooting Your System
1
Run the appropriate online diagnostics test. See "Using Server
Administrator Diagnostics" on page 153.
2
Locate the faulty power supply.
The power supply's fault indicator is lit. See "Power Indicator Codes" on
page 18.
NOTICE: You can hot-plug the power supplies. One power supply must be installed
for the system to operate. The system is in the redundant mode when two power
supplies are installed. Remove and install only one power supply at a time in a
system that is powered on. Operating the system for extended periods of time with
only one power supply installed, without a power supply blank installed, can cause
the system to overheat.
Remove the faulty power supply. See "Removing a Power Supply" on
page 76.
3
Ensure that the power supply is properly installed by removing and
reinstalling it. See "Replacing a Power Supply" on page 77.
NOTE: After installing a power supply, allow several seconds for the system
to recognize the power supply and to determine if it is working properly. The
power indicator turns green to signify that the power supply is functioning
properly. See "Power Indicator Codes" on page 18.
4
Check the indicators to see if the problem is resolved. If not, remove the
faulty power supply. See "Removing a Power Supply" on page 76.
5
Install a new power supply. See "Replacing a Power Supply" on page 77.
If the problem persists, see "Getting Help" on page 167.
Troubleshooting System Cooling Problems
Problem
Systems management software issues a fan-related error message.
Action
Ensure that none of the following conditions exist:
Ambient temperature is too high.
External airflow is obstructed.
Book.book Page 140 Monday, September 14, 2009 12:57 PM