Dell DL2000 Computer Drive User Manual


 
About Your System 27
E1811 HDD ## Rbld
Abrt
The specified hard drive
has experienced a rebuild
abort.
See "Troubleshooting a
Hard Drive" on page 146.
If the problem persists, see
your RAID
documentation.
E1812 HDD ##
Removed
The specified hard drive
has been removed from
the system.
Information only.
E1913 CPU &
Firmware
Mismatch
The BMC firmware does
not support the CPU.
Update to the latest BMC
firmware. See the BMC
User’s Guide for more
information on setup and
use of BMC.
E1A11 PCI Rsr
Config
PCI risers are not
configured correctly; some
invalid configurations may
prevent the system from
powering on.
See "Expansion-Card Riser
Boards" on page 112.
E1A12 PCI Rsr
Missing
One or all of the PCI risers
is missing, preventing the
system from powering on.
Information only.
E1A14 SAS Cable A SAS cable A is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Daughter Card" on
page 85.
E1A15 SAS Cable B SAS cable B is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Daughter Card" on
page 85.
E2010 No Memory No memory is installed in
the system.
Install memory. See
"Installing Memory
Modules" on page 102.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 27 Monday, September 14, 2009 12:57 PM