About Your System 29
E201E POST Mem Test BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 142. If problem
persists, see "Getting Help"
on page 167.
E201F DRAC Config Dell remote access
controller (DRAC)
configuration failure.
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If problem
persists, see your DRAC
documentation.
E2020 CPU Config CPU configuration failure. Check screen for specific
error messages.
E2021 Memory
Population
Incorrect memory
configuration. Memory
population order incorrect.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 142.
E2022 POST Fail General failure after video. Check screen for specific
error messages.
E2110 MBE Crd #
DIMM ## & ##
One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE). If
no memory card is present,
the "Crd #" string is left
out of the message.
See "Troubleshooting
System Memory" on
page 142.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 29 Monday, September 14, 2009 12:57 PM