28 About Your System
E2011 Mem Config
Err
Memory detected, but is
not configurable. Error
detected during memory
configuration.
See "Troubleshooting
System Memory" on
page 142.
E2012 Unusable
Memory
Memory is configured, but
not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 142.
E2013 Shadow BIOS
Fail
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 142.
E2014 CMOS Fail CMOS failure. CMOS
RAM not functioning
properly.
See "Getting Help" on
page 167.
E2015 DMA
Controller
DMA controller failure. See "Getting Help" on
page 167.
E2016 Int
Controller
Interrupt controller failure. See "Getting Help" on
page 167.
E2017 Timer Fail Timer refresh failure. See "Getting Help" on
page 167.
E2018 Prog Timer Programmable interval
timer error.
See "Getting Help" on
page 167.
E2019 Parity Error Parity error. See "Getting Help" on
page 167.
E201A SIO Err SIO failure. See "Getting Help" on
page 167.
E201B Kybd
Controller
Keyboard controller
failure.
See "Getting Help" on
page 167.
E201C SMI Init System management
interrupt (SMI)
initialization failure.
See "Getting Help" on
page 167.
E201D Shutdown Test BIOS shutdown test
failure.
See "Getting Help" on
page 167.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 28 Monday, September 14, 2009 12:57 PM