About Your System 31
Solving Problems Described by LCD Status Messages
The code and text on the LCD can often specify a very precise fault condition
that is easily corrected. For example, if the code E1418
CPU_1_Presence
appears, you know that a microprocessor is not installed in socket 1.
In contrast, you might be able to determine the problem if multiple related
errors occur. For example, if you receive a series of messages indicating
multiple voltage faults, you might determine that the problem is a failing
power supply.
Removing LCD Status Messages
For faults associated with sensors, such as temperature, voltage, fans, and so
on, the LCD message is automatically removed when that sensor returns to a
normal state. For example, if temperature for a component goes out of range,
E2119 Fatal SB Mem
CRC
One of the connections in
the FBD memory
subsystem link on the
Southbound side has
failed.
See "Troubleshooting
System Memory" on
page 142.
I1910 Intrusion System cover has been
removed.
Information only.
I1911 >3 ERRs Chk
Log
LCD overflow message.
A maximum of three error
messages can display
sequentially on the LCD.
The fourth message
displays as the standard
overflow message.
Check the SEL for details
on the events.
I1912 SEL Full System Event Log is full of
events, and is unable to log
any more events.
Clear the log by deleting
event entries.
NOTE: For the full name of an abbreviation or acronym used in this table, see the
"Glossary" on page 169.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 31 Monday, September 14, 2009 12:57 PM