Dell E05S001 Server User Manual


 
About Your System 23
Removing LCD Status Messages
For faults associated with sensors, such as temperature, voltage, fans, and so
on, the LCD message is automatically removed when that sensor returns to a
normal state. For other faults, you must take action to remove the message
from the display:
Clear the SEL—You can perform this task remotely, but you will lose the
event history for the system.
Power cycle—Turn off the system and disconnect it from the electrical
outlet; wait approximately 10 seconds, reconnect the power cable, and
restart the system.
NOTE: The following LCD status messages are displayed in the Simple format. See
"Setup Menu" on page 16 to select the format in which the messages are displayed.
Table 1-1. LCD Status Messages
Code Text Causes Corrective Actions
E1000 Failsafe
voltage
error.
Contact
support.
Check the system event log
for critical failure events.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E1114 Ambient Temp
exceeds
allowed
range.
Ambient temperature
reached a point outside the
allowed range.
See "Troubleshooting
System Cooling
Problems" on page 157.
E1116 Memory
disabled,
temp above
range. Power
cycle AC.
Memory exceeded allowable
temperature and has been
disabled to prevent damage
to the components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 157. If
the problem persists, see
"Getting Help" on
page 185.
book.book Page 23 Wednesday, February 17, 2010 6:17 PM