26 About Your System
E1414 CPU # temp
exceeding
range. Check
CPU heatsink.
Specified processor is out of
acceptable temperature
range.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processors" on page 168
and "Troubleshooting
System Cooling
Problems" on page 157.
E1418 CPU # not
detected.
Check CPU is
seated
properly.
Specified processor is
missing or bad and the
system is in an unsupported
configuration.
Ensure that the specified
processor is properly
installed. See
"Troubleshooting the
Processors" on page 168.
E141C Unsupported
CPU
configuration
. Check CPU
or BIOS
revision.
Processors are in an
unsupported configuration.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.
E141F CPU #
protocol
error. Power
cycle AC.
The system BIOS reported a
processor protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E1420 CPU Bus
parity error.
Power cycle
AC.
The system BIOS reported a
processor bus parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
Code Text Causes Corrective Actions