Dell E05S001 Server User Manual


 
About Your System 29
E1710 I/O channel
check error.
Review &
clear SEL.
The system BIOS reported
an I/O channel check.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 185.
E1711 PCI parity
error on Bus
## Device ##
Function ##.
The system BIOS reported a
PCI parity error on a
component that resides in
PCI configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 166.
PCI parity
error on Slot
#. Review &
clear SEL.
The system BIOS reported a
PCI parity error on a
component that resides in
the specified slot.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 166.
E1712 PCI system
error on Bus
## Device ##
Function ##.
The system BIOS reported a
PCI system error on a
component that resides in
PCI configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 166.
PCI system
error on Slot
#. Review &
clear SEL.
The system BIOS reported a
PCI system error on a
component that resides in
the specified slot.
Remove and reseat the
expansion-card riser that
provides the specified slot.
See "Expansion Cards and
Expansion-Card Risers"
on page 107. If the
problem persists, the riser
card or system board is
faulty. See "Getting Help"
on page 185.
Code Text Causes Corrective Actions
book.book Page 29 Wednesday, February 17, 2010 6:17 PM